Adaptive reuse projects

  • (a) Permitted use. Adaptive reuse for the conversion of any commercial building, including offices, schools, religious facilities, medical buildings, and malls into residential units or mixed-use developments is a permitted use, under the criteria described below under eligibility.

  • (b) Eligibility.

    • (1) Adaptive reuse development must include at least 50 percent of existing gross floor area developed into residential units.

    • (2) There are no environmental land use restrictions recorded on the property preventing the conversion to residential use by RIDEM or the US EPA.

  • (c) Density calculations.

    • (1) For projects that meet the following criteria, the residential density shall be no less than 15 dwelling units per acre:

      • a. Where the project is limited to the existing footprint, except that the footprint is allowed to be expanded to accommodate upgrades related to the building fire code and utility requirements; and

      • b. The development includes at least 20 percent low- and moderate-income housing; and

      • c. The development has access to public sewer and water service or has access to adequate private water, such as well and/or wastewater treatment systems approved by the relevant state agency for the entire development as applicable.

    • (2) For all other adaptive reuse projects, the residential density permitted in the converted structure shall be the maximum allowed that otherwise meets all standards of minimum housing and has access to public sewer and water services or has access to adequate private water, such as well and wastewater treatment systems approved by the relevant state agency for the entire development, as applicable.

    • (3) The density proposed for any adaptive reuse project shall be determined to meet all public health and safety standards.

  • (d) Dimensional requirements.

    • (1) Notwithstanding any other provisions of this section, existing building setbacks shall remain and are considered legal nonconforming.

    • (2) No additional encroachments shall be permitted into any nonconforming setback unless relief is granted by the permitting authority.

    • (3) Notwithstanding other provisions of this section, the height of the structure shall be considered legal nonconforming if it exceeds the maximum height of the zoning district in which the structure is located. Any rooftop construction necessary for building or fire code compliance, or utility infrastructure is included in the height exemption.

  • (e) Parking requirements.

    • (1) Adaptive reuse developments shall provide one parking space per dwelling unit. However, the applicant may propose additional parking in excess of one space per dwelling unit.

    • (2) All non-residential uses shall comply with the parking requirements of section 30-156.

  • (f) Allowed uses within an adaptive reuse project.

    • (1) Residential dwelling units are a permitted use in an adaptive reuse project regardless of the zoning district in which the structure is located, in accordance with the provisions of this section.

    • (2) Any non-residential uses proposed as part of an adaptive reuse project must comply with the provisions of section 30-71, zoning district uses, for the zoning district in which the structure is located.

  • (g) Procedural requirements.

    • (1) Adaptive reuse projects shall be subject to the procedural requirements for major land development, minor land development, or development plan review according to the standards of the Town of Burrillville Subdivision and Land Development Regulations, as amended. The administrative officer shall decide whether an adaptive reuse project will go through development plan review or minor land development or whether the project meets the threshold for major land development and shall advise the applicant as to which category of approval is required, specifically:

      • a. Development plan review may apply to any adaptive reuse project: located in a commercial zone where no extensive exterior construction of improvements is sought; or located in a residential zone which results in less than nine residential units.

      • b. Minor land development may apply to any adaptive reuse project: of up to 25,000 square feet of gross floor area located in a commercial zone where no extensive exterior construction of improvements is sought; or located in a residential zone which results in less than nine residential units.

      • c. Major land development applies to any adaptive reuse project that exceeds the thresholds for development plan review or minor land development.

    • (2) In addition to the checklist requirements for the applicable review process, the applicant shall provide the following information:

      • a. The proposed residential density and the square footage of non-residential uses.

      • b. A floor plan to scale for each building indicating, as applicable, the use of floor space, number of units, number of bedrooms, and the square footage of each unit.

(Ord. No. 12-13-2023(2); Ord. of 8-14-2024(1))