Town of Barrington
Town of Barrington Zoning Ordinance
§ 185-116

Noise impact limits

No manufacturing or business enterprise shall emit noise which, at the nearest Residence District boundary, is objectionable due to beat frequency, shrillness or intermittence. Measurement of noise shall be made at said Residence District boundary line by use of an octave band analyzer calibrated in the preferred frequencies (American Standards Association s1 6-190, Preferred Frequencies for Acoustical Measurement).

  • A. The maximum permissible sound levels measured between 7:00 a.m. and 7:00 p.m. by this method shall be as follows:
    Octave Band Center Frequency Cycles Per SecondMaximum Permitted Sound Pressure in Decibels
    31.568
    6367
    12566
    25059
    50052
    1,00046
    2,00037
    4,00026
    8,00017
  • B. Between the hours of 7:00 p.m. and 7:00 a.m., these values shall each be reduced by five decibels.